Whole Map
By selecting the Whole Map option on the View Menu after you have viewed part of a Map, you will be returned to viewing the entire map.
Part Map
The Part Map option on the View Menu allows viewing of individual rivers or reaches. The RMT software displays a window allowing you to input
the river or reach number of the river to plot. After entering the required number and clicking on OK, the individual river or reach will be displayed.
THE SETTINGS MENU
The Settings Menu allows you to select which parameters are to be activated for the current map. You can also edit the values associated with each color on the scale along
the bottom of the screen for each individual parameter. The Settings Menu can also be used to alter the color of the grid or the appearance of the background. This is particularly useful as a bitmap (.bmp) file can be used as a
background allowing you the opportunity to include further information with the map. You can also add a title to the map which will appear on the task bar as well as in the report file. Below is a summary of each of the items
found in the Settings Menu.
Parameter Settings
The Parameter Settings option on the Settings Menu allows you to select which parameters can be displayed on the Map. A window is
displayed, and you should select the required parameters by clicking the option box next to the parameter. At this stage, a tick mark will be displayed denoting the Parameters that have been activated.
Color Values
The Color Values option on the Settings Menu allows you to change the color for values, up to, but not including the value specified in
each field for each parameter. To change a color, click on CHANGE COLOR at which point a color window will be displayed. From this window you should select the new color, by clicking on the desired color and clicking on OK.
This action will not affect any other database, which will retain its original color values.
Grid Color
The Grid Color menu option on the Settings Menu allows you to change the grid color being displayed. A window will be displayed allowing
you to choose the color from a range of colors. Click the box containing the new color and then click OK. The new color should be shown when the grid is displayed.
Map Background
The Map Background option on the Settings Menu can be used to alter the appearance of the map background. When selected, a color window
will be displayed from which you should select the desired color and press OK. The Map Background will now change to the new color selected.
Map Title
The Map Title option on the Settings Menu can be used to attach a title to the Map. When selected, a window with a text box appears. After
entering the title for the map and clicking on OK, the new title will be shown at the bottom right hand side of the status bar and written to the database. When the database is loaded in the future, the new title will be shown.
THE PARAMETERS MENU
The Parameters Menu allows you to switch between each of the activated parameters. Parameters can be activated using the Parameters Settings option on the Settings Menu.
Activated parameters are highlighted in bold. The parameters that can be plotted with RMT are as follows:
- SUSPENDED SOLIDS
- BIOCHEMICAL OXYGEN DEMAND
- PERMANGANATE VALUE
- DISSOLVED OXYGEN
- TEMPERATURE
- PERCENTAGE SATURATION
- AMMONIA
- TOTAL ORGANIC NITROGEN (TON)
- PHOSPHATE
- pH
- ALKALINITY
- CHLORIDE
- TOTAL HARDNESS (TH)
- NITRITE
- NITRATE
- CONDUCTIVITY
- WATER QUALITY INDICES
- BIOLOGICAL INDICES
THE HELP MENU
The Help Menu contains access to RMT's extensive Help file and information.
THE STATUS BAR
The Status Bar is found along the bottom of the window and contains information on the progress of a file transfer, name of the open file, view and title of the map file.
THE COLOR SCALE
The Color Scale is found along the top of the status bar. On entering the Program, the values attached to each of the defined colors are given a value of zero. Once the
database has been read in, the color scale attached to each parameter will be displayed when the activated parameter has been selected. When creating a new database, the color scale has to be defined before the data can be
plotted.
RMT Hardware and Software Requirements
RMT is being developed for both 16- and 32-bit operating systems using Visual Basic language. In order to
take full advantage of RMT's current features, the following hardware and software configuration is required as a minimum:
- OPERATING SYSTEM:- WINDOWS 95/98/2000/NT
- MINIMUM PROCESSOR:- 486
- MINIMUM RAM:- 4 MB ( 8 MB RECOMMENDED )
- HARD DISK SPACE:- 5 MB FOR INITIAL INSTALLATION